What was found
FRAME FLANGE AT FR 136 STR 33-32S HAS CORROSION. REMOVED RIVETS AS NEEDED AND BLENDED CORROSION IAW SRM REV 12 53-00-00-02-09. MIN THICKNESS NOTED .046", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1, REV 8. APPLIED ALODINE AND PRIMER TO FRAME FLANGE IAW SRM 51-21-10-02-01 AND 51-25-10-02-01, REV 12. PRIOR TO ALODINE AND PRIME APPLICATION, FRAME FLANGE WAS FOUND TO BE WITHIN LIMITS IAW SRM 53-00-00-02-09, REV 12. NOMINAL THICKNESS .040". INSTALLED RIVETS IAW SRM 53-00-00-02-09. APPLIED TOP COAT AND CPC IAW SRM 53-00-00-02-09.