What was found
FLOORBEAM 19.4 HAS CORROSION AT ACFT CENTER LINE. REMOVED FWD AND AFT SPLICE TO FOM REMOVED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02, REV 12. VERIFIED CRACK FREE IAW NTM 51-00-06-910-801, PART 1, REV 8. MINIMUM REMAINING THICKNESS ON PORT SIDE BEAM IS 0.038" AND 0.040" ON STARBOARD SIDE OF BEAM. UT ACCOMPLISHED IAW NTM5 1-00-04-910-801 PART 1 REV 8. FLOORBEAM IS FOUND TO BE WITHIN LIMITS IAW RD8/4-53-5234 ISS 1. APPLIED ALODINE, PRIMER, TOPCOAT AND CPC IAW RD8/4-53-5234, ISSUE 1. COMPLIED WITH HRZ TC RD8/4-53-5234 DATED 2/27/13.