What was found
RT WING OTBD FLAP UPPER SURFACE IS CHAFED. SANDED AFFECTED AREA IAW AMM 51-25-31-370-801, REV 40. SMOOTHED OUT DAMAGE IAW SRM 57-23-30-02-02, REV 12. FOUND TO BE OUT OF LIMITS. VERIFIED AFFECTED AREAS TO BE CRACK FREE REF NDTM PART 6 TASK 51-00-01-250-801, REV 8. PERFORMED BOND TEST OF AFFECTED AREA NO DEFECT NOTED REF NTM 51-00-04-910-801 T1 REV 8. BLENDS ARE FOUND TO BE WITHIN LIMITS IAW RD8/4-57-2054 ISSUE 1. FABRICATED SHIMS IAW RD8/4-57-2054 ISSUE 1, INSTALLED SHIMS IAW SRM 57-50-40-02-03, REV 12.