What was found
FWD RUDDER LOWER PCU MOUNT LUG IS CHAFED FROM PCU ROD ENDS. BLENDED DAMAGE ON MOUNT LUG IAW SRM 55-41-20-02-01, REV 12. MECHANICALLY MEASURED BLENDED AREA AND RESULTED WITH A REMAINING THICKNESS OF .4015" IAW SRM 55-41-20-02-01, REV 12. ACCOMPLISHED FPI OF PCU MOUNT LUG AND CONFIRMED AREA OF DAMAGE TO BE CRACK FREE REF NDTM 8.2.0, REV 14. APPLIED ALODINE, PRIMER AND TOPCOAT TO WORKED AREA IAW SRM 55-41-20-02-01, REV 12. ALL DAMAGE WAS FOUND TO BE WITHIN LIMITS IAW SRM 55-41-20-02-01, REV 12.