What was found
FRAME 301, FLANGE IS CORRODED STR 33-32P. REMOVED RIVETS FROM THE FLANGE BETWEEN STR 33-32P IAW SRM 51-42-05-02-01, REV 12. PARTIALLY REMOVED CORROSION FROM FLANGE BETWEEN STR 33-32P IAW SRM 51-21-00-00-02, REV 12. REMOVED CORROSION IAW SRM 51-21-00-00-02 REV12. VERIFIED BLEND CRACK FREE IAW NTM 51-00-06-910-801, PART 1, REV8, AND MINIMUM REMAINING THICKNESS MEASURED ON FRAME WEB IS, 0.040" AND FRAME FLANGES MINIMUM MEASURED 0.037" IAW NTM 51-00-04-910-801, PART 1, REV 8. ORIGINAL THICKNESS OF FRAME IS .040" WEB IS AT ORIGINAL THICKNESS AND FLANGE IS WITHIN LIMITS IAW SRM 53-00-00-02-09, REV 12. INSTALLED RIVETS IAW SRM 51-42-05-02-01, REV 12. ALODINED AND PRIMERED FRAME PRIOR TO INSTALLATION OF RIVETS IAW SRM 51-21-10-02-01 & 51-25-10-02-01 REV 12 TOP COAT PAINTED AFTER RIVETS INSTALLED IAW SRM 51-25-15-02-01, REV 12. APPLIED CPC TO WORKED AREA IAW AMM 51-25-01-390-801 REV 40. PRIMED & PAINTED EXTERIOR IAW SRM 51-25-10-02-01 & SRM 51-25-05-02-01 REV 12.