What was found
STRINGER 25S HAS CORRODED RIVETS AND POSSIBLE CORROSION STA 689-714.6. REMOVED RIVETS C/T STRINGER, REMOVED LIGHT SURFACE CORROSION IAW SRM 51-21-00-00-02 TOTAL 13 RIVETS SRM 51-42-05-02-01, REV 12 MIN THICKNESS NOTED .045", CONFIRMED CRACK FREE IN AFFECTED AREA REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801, PT 1 REV 8. STRINGER FOUND TO BE WITHIN LIMITS IAW RD8/4-53-5283, ISSUE 1. INSTALLED 13 RIVETS IAW SRM 51-42-05-02-01, REV 12. APPLIED SURFACE PROTECTION TO WORKED AREA IAW SRM 51-25-15-02-01, REV 12. APPLIED CIC TO WORKED AREA IAW AMM 51-25-01-390-801, RV 40. APPLIED EXTERIOR TOPCOAT IAW AMM 51-25-31-370-801, REV 40. COMPLIED WITH TC RD8/4-53-5283, WO 143401.