What was found
SKIN STRAP FORWARD OF STA -18.25 HAS POSSIBLE CORROSION STR 31S-32S. REMOVED RIVETS FOR ACCESS IAW SRM REV 12 51-42-05-02-01. BLENDED CORROSION IAW SRM REV 12 51-21-00-00-02. MIN THICKNESS NOTED .037", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1, REV 8. SKIN STRAP IS WITHIN LIMITS OF RD8/4-53-5288 ISSUE 1. INSTALLED RIVETS THAT WERE REMOVED FOR ACCESS IAW SRM 51-42-05-02-01, REV 12. APPLIED SURFACE PROTECTION TO WORKED AREA IAW SRM 51-25-15-02-01, REV 12. APPLIED CPC IAW AMM 51-25-01-390-801, REV 40. COMPLIED WITH TC RD8/4-53-5288.