What was found
FRAME 644.5 IS CORRODED STR 33-32P. REMOVED RIVETS C/T FRAME 644.5 STR 33-32P FLANGE. REMOVED CORROSION FROM FRAME WEB AND FLANGE IAW SRM REV 12 51-42-05-02-01 AND 51-21-00-00-02. MIN THICKNESS NOTED .035", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801, PT 1, REV 8. FOUND TO BE WITHIN LIMITS IAW RD8/4-53-5280 ISSUE 1. APPLIED SURFACE PROTECTION IAW RD8/4-53-5280 ISSUE 1. INSTALLED RIVETS IAW RD8/4-53-5280 ISSUE 1. APPLIED TOPCOAT AND CPC IAW RD8/4-53-5280 ISSUE 1. COMPLIED WITH TC RD8/4-53-5280, WO 143401.