What was found
FRAME 258.5, FLANGES ARE CORRODED STR 27P-30P. REMOVED 7 RIVETS AND CORROSION FROM FRAME 258.5 FLANGES BETWEEN STR 27P-30P IAW SRM (R12) 51-42-05-02-01 AND SRM (R12) 53-00-00-02-09. REMOVED CORROSION FROM FRAME 258.5 WEB BETWEEN STR 28P TO 29P IAW SRM (R12) 51-21-00-00-02. FOUND FRAME 258.5 WEB BETWEEN STR 28P TO 29P TO BE OUT OF LIMITS IAW SRM (R12) 53-30-15-00-01 STEP 2, ITEM 21, MIN THICKNESS NOTED .038", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801, PT 1, REV 8 & 51-00-06-910-801, PT 1 REV8. FRAME NOMINAL THICKNESS .040" IAW SRM 53-30-15-00-01, REV 12. FRAME FLANGES ARE IN LIMITS IAW SRM 53-00-00-02-09, REV12. APPLIED ALODINE AND PRIMER IAW SRM 51-21-10-02-01, 51-75-10-02-01 REV 12. INSTALLED RIVETS IAW SRM 51-42-05-02-01, REV 12. APPLIED TOPCOAT AND CPC IAW SRM 51-25-15-02-01 REV12, AMM 51-25-01-390-801 REV40. FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-5287 ISSUE NR 1. COMPLIED WITH TC RD 8/4-53-5287 WO 43401.