What was found
FRAME 668.9, FLANGE IS CORRODED AT STR 24P. STARTED REMOVING CORROSION FROM FRAME FLANGE IAW SRM, REV 12 51-21-00-00-02. REMOVED CORROSION IAW SRM 51-21-00-00-02, REV 12. REMOVED INTERCOSTAL AND GUSSET AT FRAME 668.9 + STR 24P TO FOM IAW SRM 51-40-15-02-01 REV 12. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801, PT1, REV 8. OK TO INSTALL INTERCOSTAL & GUSSET. FRAME MIN REMAINING THICKNESS IS .063 AND IS WITHIN LIMITS IAW RD8/4-53-5300 ISSUE 1 DATED 20, MAR 2013. INSTALLED INTERCOSTAL AND GUSSET IAW SRM 51-40-15-02-01, REV 12. SPOT FACED 2 HOLES IN FRAME IAW RD8/4-53-5300, ISSUE 1, INSTALLED FASTENERS IN FRAME IAW RD8/4-53-5300 ISSUE 1, APPLIED SURFACE PROTECTION AND AV-8 IAW RD8/4-53-5300 ISSUE 1. COMPLIED WITH TC RD8/4-53-5300/3 WO 143401.