What was found
STRINGER 24P HAS CORRODED RIVETS AND POSSIBLE CORROSION BS 258.5-301. REMOVED CORRODED RIVETS IAW SRM 51-42-05-02-01, REV 12. REMOVED LIGHT CORROSION ON STRINGER IAW SRM 51-21-00-00-02, REV 12. 100 PERCENT MATERIAL LOSS, OUT OF LIMITS. REMOVED DAMAGED STRINGER SECTION IAW RD8/4-53-5282, ISSUE 1. ACCOMPLISHED FPI OF CUT LINE IAW RD8/4-53-5282 ISSUE 1 AND NDTM 8.2.0 REV 14 AREA WAS FOUND TO BE CRACK FREE. MATCH DRILLED IAW RD8/4-53-5282 ISS 1. ALODINED AND PRIMED AS REQUIRED IAW RD8/4-53-5282, ISS 1. INSTALLED STRINGER IAW RD8/4-53-5282 ISS 1. APPLIED TOPCOAT IAW SRM 51-25-10-02-01 REV 12, 51-25-15-02-01 REV1 2 AND 51-25-05-02-01 REV 12. APPLIED CPC IAW AMM REV 40 51-25-01-390-801. COMPLIED WITH TC RD8/4-53-5282.