What was found
FRAME 449.5 FLANGE IS CORRODED STR 31P-32P. REMOVED 6 RIVETS IN FLANGE IAW SRM 51-42-05-02-01, REV 12. REMOVED CORROSION ON FLANGE 449.5 STR 31P-32P IAW SRM 51-21-00-00-02, REV 12. REMOVED CORROSION ON FRAME WEB 449.5 IAW SRM 51-21-00-00-02, REV 12. REMOVED 6 RIVETS FWD OF FLANGE IN SKIN STRAP, AND 2 RIVETS FWD OF FLANGE IN STR 31P TO FOM IAW SRM 51-42-05-02-01, REV 12 MIN THICKNESS NOTED .059", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT1 & 51-00-06-910-801 PT 1 REV 8. BLENDED AREA FOUND TO BE WITHIN LIMITS IAW RD8/4-53-5286 ISSUE NR 1 ALODINED AND PRIMED BLENDED AREA IAW RD8/4-53-5286 ISSUE NR 1. OK TO INSTALL RIVETS. INSTALLED RIVETS IAW SRM 51-42-05-02-01, REV 12. RESTORED SURFACE PROTECTION AND CPC IAW RD8/4-53-5286 ISSUE NR 1. COMPLIED WITH RD 8/4-53-5286, WO 143401.