What was found
FRAME 584.5 FLANGE IS CORRODED STR 31P-32P. REMOVED FASTENERS AT BS 584.5STR 31P-32P TO FOM IAW SRM 51-42-05-02-01, REV 12. REMOVED CORROION FROM FLANGE IAW SRM 53-00-00-02-09 REV 12. REMOVED CORROSION FROM FRAME WEB IAW SRM 53-00-00-02-09, REV 12. MIN THICKNESS NOTED .044", CONFIRMED AFFECTEFD AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801, PT 1, REV 8. APPLIED ALODINE AND PRIMER IAW SRM 51-21-10-02-01, 51-25-10-02-01 REV 12. INSTALLED RIVETS IAW SRM 51-42-05-02-01, REV 12. APPLIED TOPCOAT AND CPC IAW SRM 51-25-15-02-01 REV 12, AMM 51-25-01-390-801, REV 40. PRIOR TO THE ABOVE BLENDED AREA FOUND TO BE WITHIN LIMITS IAW RD8/4-53-5293 ISSUE 1, DATED 14MAR2013. APPLIED EXTERIOR SURFACE PROTECTION IAW SRM 51-25-10-02-01 AND 51-25-15-02-01 REV 12. COMPLIED WITH RD8/4-53-5293 WO 143401.