What was found
EXTERNAL FUSELAGE BELLY SKIN HAS A DENT OR PREVIOUS UNMARK BLEND AFT OF STA X19.4 BETWEEN STRINGERS 31P AND 32P. REMOVED PAINT IAW SRM 51-26-10-02-01, REV 12. MECHANICALLY MEASURED .5 X .5 AND .010 DEEP. BLEND IS OUT OF LIMITS IAW SRM 53-00-00-02-02 REV 12 MIN THICKNESS NOTED .059", CONFIRMED CRACK FREE IN AFFECTED AREA REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801, PT 1 REV 9. DAMAGED SKIN FOUND TO BE WITHIN LIMITS IAW RD8/4-53-5307, ISSUE 1, DATED 3-18-13. APPLIED ALODINE, PRIMER AND TOPCOAT IAW SRM 51-21-10-02-01, 51-25-10-02-01, 51-25-45-02-01, 51-25-15-02-01 REV 12. APPLIED YELLOW DOT IAW GPM 10.11.3 REV 45 SEE EAS NR 19 WO 121693 FOR DMI DETAILS. COMPLIED WITH TC RD8/4-53-5307, WO 143401.