What was found
RT WING TO FUSELAGE FAIRING AT BS 42 HAS BARE METAL AND FRETTING CORROSION WHERE IT MATES WITH PANEL 611AR. BLENDED FRETTING IAW SRM 51-14-00-02-03, REV 12 MIN THICKNESS NOTED .076", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801, PT 1, REV 8. ALODINED AND PRIMED IAW SRM 51-21-10-02-01 AND SRM 51-25-10-02-01, REV 12. APPLIED EXTERIOR TOPCOAT IAW SRM 51-25-15-02-01, REV 12 MIN THICKNESS NOTED IS .076 WHICH IS WITHIN LIMITS IAW RD8/4-53-5324, SECTION 1, SHEET 1, DATED 2013-03-19, ISS 1. TOPCOAT APPLIED IAW SRM 51-25-15-02-01, REV 12, PG 18. COMPLIED WITH TC RD8/4-53-5324, WO 143401.