What was found
STRINGER 24S HAS CORROSION AT STA 714.6. REMOVED CORROSION IAW SRM 51-21-00-00-02, REV 12. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801, PT 1 & 51-00-06-910-801 PT 1, REV 8. BLENDED AREA IS WITHIN LIMITS IAW RD8/4-5-3-5305, ISSUE 1. ALODINED & PRIMED BLENDED AREA IAW RD8/4-5-3-5305 ISSUE 1. APPLIED PRIMER TO INTERIOR AND EXTERIOR TOP COATED AND APPLIED CPC IAW SRM 51-25-10-02-01, 51-25-45-02-01, 51-25-15-02-01 REV12 AND AMM 51-25-01-370-801, REV 40.