What was found
CHAFE DAMAGE ON LT ENGINE A8 EMS STRUT AFT LOWER SIDE. REMOVED AND BLENDED DAMAGE IAW SRM 51-14-00-02-04, REV 12. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801, PT 1, REV 9. BLENDED FOUND TO BE OUT OF LIMITS IAW SRM 54-13-06-00-01, REV 12. MEASURED BLENDED AREA TO BE .2" & .225" BY .004" DEEP. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD8/4-54-1118, ISSUE 1. VERIFIED AREA TO BE FREE & CLEAR OF OBSTRUCTIONS. COMPLIED WITH TC RD8/4-54-1118, WO143401.