What was found
CHAFE DAMAGE ON AFT SERVICE DOOR SURROUND STRUCTURE AT THE 12:00 POSITION. CHEMICALLY REMOVED PAINT FROM CHAFE AREA FOR FURTHER EVALUATION IAW SRM 51-26-10-02-01. BLENDED AREA TO CONTOUR USING SCOTCHBRITE PAD. FOUND CHAFE TO BE .40" L .30" W AND MAX DEPTH OF .003. BLEND FOUND TO BE ACCEPTABLE FOR CONTINUED SERVICE IAW RD 8/4-53-5349. PERFORMED NDT INSPECTION OF THE AFT SERVICE DOOR SURROUND STRUCTURE IAW NDT MANUAL, PT 1 51-00-06-910-801 AND PT 6 51-00-01-250-801 EDDY CURRENT METHOD. NO DEFECTS NOTED. LODINED, PRIMED AND PAINTED IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-15-02-01. ALL WORK PERFORMED IAW TC RD 8/4-53-5349.