What was found
CHAFING DAMAGE ON AFT CARGO DOOR FWD OF AFT HINGE. REMOVED HINGE FOM. BLENDED AREA TO CONTOUR USING SCOTCH BRITE PADS. BLENDED AREA MEASURES .17" L .06" W AND .008" D. SENT TO ENGINEERING. BLENDED AREA FOUND TO BE WITH IN ACCEPTABLE LIMITS IAW RD 8/4-52-940. PERFORMED NDT INSPECTION OF THE AFT CARGO DOOR IAW NDT MANUAL PT 1 51-00-06-910-801 AND PT 6 51-00-01-250-801 EDDY CURRENT METHOD, NO DEFECTS NOTED. TREATED, PRIMED AND REINSTALLED HARDWARE IAW TC RD 8/4-52-940. ALL WORK PERFORMED IAW TC RD 8/4-52-940.