What was found
FRAME X49.500 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 31P AND 33. REMOVED RIVETS AND CORROSION IAW SRM 51-42-05-02-01, REV 12, SRM 51-21-00-00-02 REV12. MIN. THICKNESS NOTED 050", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 & 51-00-06-910-801 PT 1 REV 9. NOMINAL THICKNESS .050", FOUND TO BE WITHIN LIMITS SRM 53-00-00-02-09, REV12. APPLIED ALODINE AND PRIMER IAW SRM 51-21-10-02-01, 51-25-10-02-01, REV 12. INSTALLED RIVETS IAW SRM 51-42-05-02-01, REV 12. APPLIED TOPCOAT AND CPC IAW SRM 51-25-15-02-01, REV 12 AND AMM 51-25-01-390-801 REV 42.