What was found
FRAME X156.000 LOWER FLANGE HAS CORROSION BETWEEN STRINGERS 31P AND 32P. REMOVED 2 RIVETS AND CORROSION FROM FRAME X156.000 LOWER FLANGE BETWEEN STRINGERS 31P-32P IAW SRM (REV.12) 53-00-00-02-09. MIN NOTED THICKNESS .047" REF NTM 51-00-04-910-801, PT1, REV9. CONFIRMED CRACK FREE REF NTM 51-00-04-910-801, PT1, REV 9. NOMINAL THICKNESS .040 FRAME IN LIMITS IAW SRM 53-00-00-02-09, REV 12. APPLIED ALODINE AND PRIMER, INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01, 51-42-05-02-01, REV12. APPLIED INTERIOR TOPCOAT IAW SRM 51-25-15-02-01, REV12. APPLIED AV-8 COATING TO AFFECTED AREA AT FRAME 156.000 STRINGER 31P AND 32P IAW AMM 51-25-01-390-801, REV 42.