What was found
FRAME X156.000, LOWER FLANGE HAS CORROSION BETWEEN STRINGERS 30S AND 31S. REMOVED 6 RIVETS AND CORROSION FROM FRAME X156.000 LOWER FLANGE BETWEEN STRINGERS 30 AND 31S IAW SRM (REV 12) 53-00-00-02-09. MIN NOTED THICKNESS .043" REF NTM 51-00-04-910-801, PT 1, REV9. CONFIRMED CRACK FREE REF NTM 51-00-06-910-801, PT 1, REV 9. NOMINAL THICKNESS .040 FRAME IN LIMITS IAW SRM 53-00-00-02-09, REV 12. APPLIED ALODINE AND PRIMER AND INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-23-10-02-01, 51-42-05-02-01 REV12. APPLIED INTERIOR TOPCOAT IAW SRM 51-25-15-02-01, REV 12. APPLIED AV8 COATING TO AFFECTED AREA BETWEEN STRINGERS 305 AND 315 AT FRAME 156.000 IAW AMM 51-25-01-390-801, REV42.