What was found
FRAME X176.000, LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 29S AND 32S. REMOVED RIVETS AND CORROSION IAW SRM 53-00-00-02-09, REV12. MIN NOTED THICKNESS .043" REF NTM 51-00-04-910-801, PT 1, REV 9. CONFIRMED CRACK FREE REF NTM 51-00-06-910-801, PT 1, REV9. NOMINAL THICKNESS .040 FRAME IN LIMITS IAW SRM 53-00-00-02-09, REV 12. APPLIED ALODINE AND PRIMER, INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01, 51-42-05-02-01, REV12. APPLIED INTERIOR TOPCOAT IAW SRM 51-25-15-02-01, REV 12. APPLIED AV8 COATING TO AFFECTED AREAS AT FRAME 176.000 BETWEEN STRINGERS 295 AND 325 IAW AMM 51-25-01-390-801, REV42.