What was found
FRAME 449.5, FLANGE IS CORRODED STR 31S-32S. REMOVED 4 RIVETS AND CORROSION FROM FRAME 449.5 FLANGE BETWEEN STR 315-325 IAW SRM, REV12 53-00-00-02-09 MIN THICKNESS NOTED .065", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 & 51-00-06-910-801 PT 1 REV9. NOMINAL THICKNESS .063 FOUND BLENDS TO BE WITHIN LIMITS IAW SRM 53-00-00-02-09 REV12. ALODINED AND PRIMED AREA AND INSTALLED 4 EA RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01 REV12. APPLIED ALUMINIED PRIMER AND CPC TO AREA IAW SRM 51-25-15-02-01, REV 12 AND AMM 51-25-01-390-801, REV 42. APPLIED PRIMER AND TOPCOAT TO EXTERIOR REPAIR AREA IAW SRM 51-25-10-02-01 AND 51-25-05-02-01, REV 12.