What was found
FRAME X301.000, LOWER FLANGE HAS CORROSION BETWEEN STRINGERS 29P AND 30P. REMOVED 3 RIVETS FROM FRAME FLANGE 301 AND CORROSION BETWEEN STRINGERS 29P AND 30P IAW SRM 51-42-05-02-01, REV 12, SRM 51-21-00-00-02, MIN THICKNESS .045" REF NTM 51-00-04-910-801 PT1, REV 9 CONFIRMED CRACK FREE REF NTM 51-00-06-910-801, PT1, REV 9 MATERIAL LOSS FOUND TO BE IN LIMITS IAW SRM 53-00-00-02-09 AND SRM 53-30-15-00-01, REV 12 NOMINAL THICKNESS IS .040 IN ALODINED, PRIMED AND INSTALLED RIVETS IAW SRM 51-21-10-02-01 AND 51-25-10-02-01 AND 51-42-05-02-01, REV 12 PRIMED AND TOP COATED INTERIOR AND EXTERIOR REPAIR AREAS IAW SRM 51-25-10-02-01 AND 51-25-05-02-01 AND 51-20-00-00-01, REV 12 APPLIED CPC IAW AMM 51-25-01-390-801, REV 42.