What was found
FRAME X341.000 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 31S AND 33. REMOVED RIVETS AND CORROSION FROM FRAME FLANGES AT FRAME 341 FROM STRINGER 31S TO 33 IAW SRM 51-42-05-02-01, SRM 51-21-00-00-02, REV12 MIN THICKNESS NOTED .050" REF NTM 51-00-04-910-801 PT 1 REV9. CONFIRMED CRACK FREE REF NTM 51-00-06-910-801, PT 1, REV9. MATERIAL LOSS FOUND TO BE IN LIMITS IAW SRM 53-00-00-02-09 AND 53-30-15-00-01, REV 12, NOMINAL THICKNESS IS .050". ALODINED AND PRIMED. INSTALLED RIVETS IAW SRM 51-21-10-02-01 AND 51-25-10-02-01 AND 51-42-05-02-01, REV 12. PRIMED AND TOPCOATED INTERIOR & EXTERIOR REPAIR AREAS IAW SRM 51-25-10-02-01 AND 51-25-05-02-01 AND 51-20-00-00-01, REV12. APPLIED CPC IAW AMM 51-25-01-390-801, REV42.