What was found
BLENDED CORROSION, APPROX 60 PERCENT MATERIAL LOSS FOUND STRINGER TO BE OUT OF LIMITS IAW SRM 53-40-03-00-01, REV 12. REMOVED STRINGER IAW SRM 51-42-05-02-01, REV 12. MATCH DRILLED NEW STRINGER IAW SRM 51-40-07-02-01, REV 12. INSTALLED STRINGER IAW SRM 51-42-05-02-01, REV 12.