What was found
FOUND CORROSION ON FRAME X156.000, LOWER FLANGE BETWEEN STRINGERS 32S AND 33. FOUND CORROSION AT RIVET BUCKTAILS ON 4 EA RIVETS. REMOVED RIVETS 4 EA AT FRAME X156.000 LOWER FLANGE BETWEEN STRINGERS 32S AND 33 IAW SRM 51-40-07-02-01 REV 12. CLEAN CORROSION ON FRAME X156.000, LOWER FLANGE BETWEEN STRINGERS 32S AND 33 IAW SRM 51-21-00-00-02, STEPS 1-4A, 1, 2, A, B, REV 12. MIN NOTED THICKNESS .042", CONFIRMED CRACK FREE REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801, PT 1, REV 9. MATERIAL LOSS IS WITHIN LIMITS WITH NOMINAL OF 0.040" SRM 53-00-00-02-09 AND SRM 53-20-15-00-01, REV 12. ALODINED, PRIMED AND INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01, 51-42-05-02-01, REV 12. APPLIED INTERIOR TOPCOAT AND CPC IAW SRM 51-25-15-02-01, REV 12. AMM 51-25-01-390-801, REV 42. PRIMED AND PAINTED EXTERIOR SURFACE AT FRAME STA X156 IAW SRM 51-25-05-02-01, REV 12.