What was found
RT FLOORBEAM X19.400 LOWER STIFFENER FLANGE HAS CORROSION UNDER PULLEY QUADRANT STRUCTURE. REMOVED CORROSION, FOUND STIFFENER OUT OF LIMITS NO REPAIRS ALLOWED IAW SRM 51-21-00-00-02, 53-20-43-0-01, REV 12. CONFIRMED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1, REV 9. MECHANICALLY MEASURED STIFFENER .047" MIN REMAINING THICKNESS. FOUND BLENDS TO BE WITHIN LIMITS IAW RD8/4-53-5372 ISS, NR 1. ALODINED AND PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01, REV 12. TOPCOATED AND APPLIED CPC IAW SRM 51-25-15-02-01, REV 12 AND AMM 51-25-01-390-801, REV 42. COMPLIED WITH TC RD8/4-53-5372, WO 143293.