What was found
FRAME X71.200, LOWER FLANGES AND VERTICAL WEB HAVE CORROSION BETWEEN STRINGERS 30S AND 31S. REMOVED 6 RIVETS IAW SRM 51-42-05-02-01, REV 12. REMOVED 1 RIVET FROM VERTICAL WEB AND REMOVED CORROSION FROM FRAME FLANGES IAW SRM 51-42-05-02-01, REV 12 AND SRM 53-00-00-02-09, REV 12. VERIFIED AFFECTED AREAS TO BE CRACK FREE REF NDTM PART 6, TASK 51-00-01-250-801, REV 9 MIN THICKNESS NOTED .036" REF NDTM PART 4, TASK 51-00-02-250-801, REV 9. REMAINING MATERIAL IS WITHIN ALLOWABLE LIMITS IAW RD8/4-53-5399. ALODINED, PRIMED AND INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01, 51-42-05-02-01, REV 12. APPLIED INTERIOR TOPCOAT AND CPC IAW SRM 51-25-15-02-01, REV 12, AMM 51-25-01-390-801, REV 42. PRIMED AND PAINTED EXTERIOR SURFACE AT FRAME STA X71.200 IAW SRM 51-25-05-02-01, REV 12. COMPLIED WITH TC RD8/4-53-5399, WO 143293.