What was found
UPPER CARGO COMPARTMENT FLOOR LEVEL GUSSET ON FRAME BS 789.1 LT IS CHAFED FROM THE FLOOR PANEL. REMOVED GUSSET IAW SRM 51-42-05-02-01, REV 12 AND SRM 51-40-15-02-01, REV 12. REMOVED CHAFED DAMAGE FROM GUSSET IAW SRM 51-14-00-02-03, REV 12. LOCATED AND DRILLED NEW GUSSET IAW SRM 51-40-07-02-01, REV 12. INSTALLED GUSSET IAW SRM 51-42-05-02-01 AND REV 12, SRM 51-40-15-02-01, REV 12. NOTE: NO ALLOWABLE LIMITS FOR GUSSET IAW SRM 53-40-52-00-01, ITEM 55, REV 12.