What was found
STRINGER 24P SPLICE, HAS A SPOT OF CORROSION AFT OF STA 564.5. REMOVED SPLICE IAW SRM 51-42-05-02-01, REV 12, DATED OCT 05/2012. NOTE: PRIOR TO REMOVING SPLICE FOUND SPLICE TO BE CORRODED OUT OF LIMITS NO DAMAGE ALLOWED IAW SRM 53-30-03-00-01, REV 12. MATCH DRILLED NEW STRINGER 24P AT STA 564.5 IAW SRM 51-42-05-02-01, SRM 51-40-15-02-01, REV 12. PRIMED, PAINTED SPLICE IAW SRM 51-25-10-02-01 AND 51-25-15-02-01, REV 12. APPLIED CPC IAW AMM 51-25-01-390-801, REV 42.