What was found
FRAME X32.400 LOWER FLANGES AND VERTICAL WEB HAVE CORROSION BETWEEN STRINGERS 30P AND 32P. REMOVED RIVETS TO ACCESS CORROSION IAW SRM REV 12 53-00-00-02-09, REPAIR 09 STEP 6(A). REMOVED CORROSION FROM FRAME X32.400 LOWER FLANGES BETWEEN STRINGER 30P-32P IAW SRM REV 12 53-00-00-02-09, REPAIR-09, STEP 6(A). REMOVED CORROSION FROM FRAME X32.400 VERTICAL WEB BETWEEN 30P AND 32P IAW SRM REV 12 51-21-00-00-02. MIN THICKNESS NOTED OF FLANGE IS 0.38", ON WEB IS 0.035" IAW NTM 51-00-04-910-801, PT 1, REV 9. VERIFIED AFFECTED AREA TO BE CRACK FREE USING HFEC REF NDTM PART 1, TASK 51-00-06-910-801, REV 9. REMAINING MATERIAL THICKNESS 0.38 ON FLANGE AND 0.035 ON WEB IS WITHIN ALLOWABLE LIMITS IAW RD8/4-53-5393. ALODINED AND PRIMED AREA BETWEEN FRAME 32.4, FLANGE AND VERT WEB AND STRINGERS 30P AND 32P IAW SRM 51-21-00-00-02, REV 12, STEPS 4A(2)(C)(D). FOUND ADDITIONAL CORROSION ON FWD SIDE OF FRAME BETWEEN STRINGER 30P-31P. REMOVED CORROSION IAW SRM 51-21-00-00-02, REV 12 MIN THICKNESS NTOED .034" IAW NTM 51-00-04-910-801 PT 1, REV 9. CONFIRMED CRACK FREE IN BLENDED AREA REF NTM 51-00-06-910-801 PT 1, REV 9. MATERIAL LOSS IS WITHIN LIMITS IAW RD8/4-53-5393 ISS 2. INSTALLED RIVETS IAW SRM 51-42-05-02-01, REV 12. CLEANED, PRIMED AND APPLIED ALUMINIZED TOP COAT IAW SRM 51-25-10-02-01 AND SRM 51-25-15-02-01, REV 12. APPLIED CPC TO SURFACE IAW AMM 51-25-01-390-801, REV 42. COMPLIED WITH TC RD8/4-53-5393, WO 143293.