What was found
STRINGER 24S, SPLICE AT STA 100.8 IS CORRODED. REMOVED CORROSION FOUND SPLICE, TO BE OUT OF LIMITS DUE TO NO REPAIRS ALLOWED IAW SRM 51-21-00-00-02, 53-20-03-00-01, REV 12. REMOVED STRINGER SPLICE IAW SRM 51-42-05-02-01, REV 12. MATCH DRILLED NEW STRINGER SPLICE IAW SRM 51-40-01-02-01, REV 12, OK TO INSTALL. INSTALLED NEW SPLICE IAW SRM 51-42-05-02-01, REV 12. CLEANED, PRIMED, AND PAINTED EXTERIOR SURFACE IAW SRM 51-25-05-02-01, REV 12. CLEANED, PRIMED AND APPLIED ALUMINIZED TOP COAT TO INTERIOR SURFACE IAW SRM 51-25-10-02-01, REV 12 AND SRM 51-25-15-02-01, REV 12. APPLIED CPC TO SURFACE IAW AMM 51-25-01-390-801, REV 42.