What was found
FRAME X19.400, UPPER FLANGE ABOVE STRINGER 30S HAS CORROSION. CLEANED AND SANDED UPPER FLANGE IAW SRM 51-26-00-02-03. MIN THICKNESS NOTED .035" REF NTM 51-00-04-910-801, PT 1 REV 9. VERIFIED AFFECTED AREAS TO BE CRACK FREE, REF NDTM PART 1, TASK 51-00-06-910-801, REV9. FLANGE FOUND TO BE WITHIN LIMITS IAW RD8/4-53-5371, ISSUE 1 DATED 29APR2013. ALODINED AND PRIMED IAW RD8/4-53-5371, ISSUE 1, DATED 29APR2013. RESTORED SURFACE PROTECTION IAW RD8/4-53-5371, ISS 1. COMPLIED WITH TC RD8/4-53-5371, WO143293.