What was found
FRAME BS 258.5 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 29S AND 32S. REMOVED CORROSION ON LOWER FLANGES IAW SRM 51-21-00-00-02, REV 12. VERIFIED AFFECTED AREAS TO BE CRACK FREE, REF NDTM PART 1, TASK 51-00-06-910-801, REV 9. BLENDS BETWEEN STR 32-30S WITHIN LIMITS IAW SRM 53-00-00-02-09, REV 12. BLENDS BETWEEN STR 30-29S WITHIN LIMITS IAW RD8/4-53-5398, ISS 1. ALODINED AND PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01 REV 12. INSTALLED RIVETS IAW SRM 51-42-05-02-01, REV 12. ALODINED, PRIMED, TOP COATED AND APPLIED CPC TO AREA IAW SRM 51-21-10-02-01, REV 12, SRM 51-25-10-02-01 REV 12, SRM 51-25-15-02-01, REV 12 AND AMM 51-25-01-390-801, REV 42. COMPLIED WITH TC RD8/4-53-5398, WO 143293.