What was found
STRINGER 24P CORRODED, BS 664-669. REMOVED CORROSION IAW SRM REV12 51-21-00-00-02. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801, PT 1 REV 9. FOUND WITHIN LIMITS IAW RD NR 8/4-53-5389, ISSUE 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 24P CORRODED, BS 664-669. REMOVED CORROSION IAW SRM REV12 51-21-00-00-02. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801, PT 1 REV 9. FOUND WITHIN LIMITS IAW RD NR 8/4-53-5389, ISSUE 1.