What was found
CORROSION ON SKIN, BS 1.-6.7 AND 26.7-32.4, STRINGERS 25P -24P. REMOVED CORROSION IAW SRM 51-21-00-00-02, REV 12. PERFORMED FLUORESCENT PENETRANT INSPECTION IAW NDTM 8.2.1.1, REV 14, NO CRACKS DETECTED. FOUND TO BE WITHIN LIMITS IAW RD8/4-53-5373, ISSUE 1 DATED, 27APRIL2013. RESTORED SURFACE PROTECTION IAW RD8/4-53-5373, ISSUE NR 1 DATED 27 APRIL 2013.