As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 2 ENGINE INTAKE BYPASS DOOR CLOSED (GREEN) LIGHT IMMEDIATELY ILLUMINATED WHEN PUSH BUTTON SWITCH PUSHED OUT. RETURNED TO FIELD, LANDING UNEVENTFUL. REPLACED NR 2 ENGINE INTAKE BYPASS DOOR ACTUATOR ASSY IAW AMM 71-61-06-000-801/400-801. OPS CHECK GOOD. SWITCH LIGHT OPERATES PROPERLY. RETURNED TO SERVICE.