What was found
FRAME 564.5, FLANGE AND WEB ARE CORRODED STR 31P-30P. REMOVED STRINGER 31P FITTING AND RIVETS ON X564.2 FOR ACCESS, BLENDED CORROSION ON FRAME 564.5 BETWEEN STR 31P-30P IAW SRM REV 12 51-42-05-02-01, 51-40-15-02-01, AND 51-21-00-00-02. CONFIRMED AREA CRACK FREE REF NTM 51-00-06-910-801, PT REV 9. MIN THICKNESS REMAINING NOTED ON WEB 0.056", ON FLANGE 0.046" NTM 51-00-04-910-801 PT 1, REV 9. VERIFIED AFFECTED AREA TO CRACK FREE USNG HFEC. REF NDTM PART 1, TASK 51-00-06-910-801, REV 9. FOUND BLENDS IN LIMITS IAW RD8/4-53-5392 ISS 1. ALODINED & PRIMED IAW SRM 51-21-10-02-01, 51-25-10-02-01, & 51-25-45-02-01(R12). INSTALLED RIVETS COMMON TO FRAME FLANGE IAW SRM 51-42-05-02-01 (R12). INSTALLED STR 31P FITTING IAW SRM 51-42-05-02-01, &51-40-15-02-01 (E12). APPLIED ALUMINIZED PAINT AND CPC IAW RD 8/4-53-5392 ISS 1. COMPLIED WITH TC RD8/4-53-5392, W/O 143293 DATED 04-11-13. APPLIED EXTERIOR PRIMER & TOP COAT IAW SRM 51-25-45-02-01.