What was found
FRAME 1.0 FLANGE IS CORRODED STR 31P-32P. REMOVED RIVETS AND CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN THICKNESS NOTED .046" REF NTM 51-00-04-910-801 PT 1. CONFIRMED CRACK FREE REF NTM 51-00-06-910-801, PT 1. APPLIED ALODINE AND PRIMER, INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. RESTORED SURFACE PROTECTION IAW SRM 51-25-15-02-01, 51-25-45-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801. BLENDS FOUND IN LIMITS IAW RD 8/4-53-5491. COMPLIED WITH TC RD 8/4-53-5491.