What was found
FRAME 49.5 IS CORRODED BY STRINGER 31P. REMOVED CROSS BRACE, STRINGER CLIP AND STANCHION FOM IAW SRM 51-41-05-00-01 AND 51-42-05-02-01. STANCHION FOUND OUT OF LIMITS IAW SRM 53-20-43-00-01. FRAME FOUND OUT OF LIMITS IAW SRM 53-20-15-00-01. REMOVED FAME SEGMENT IAW RD 8/4-53-5483, MATCH DRILLED NEW FRAME SEGMENT IAW RD 8/4-53-5483. FABRICATED REPAIR SPLICE AND STRAP IAW RD 8/4-53-5483. ALODINED, PRIMED AND TOPCOATED IAW RD 8/4-53-5483. VERIFIED AFFECTED AREAS TO BE CRACK FREE REF NDTM PT 6 51-00-01-250-801. INSTALLED NEW FRAME SEGMENT IAW RD 8/4-53-5483. MATCH DRILLED NEW STANCHION IAW SRM 51-40-07-02-01 AND INSTALLED STANCHION AND PREVIOUSLY REMOVED STRINGER CLIP IAW SRM 51-42-05-02-01. RESTORED SURFACE PROTECTION IAW SRM 51-25-45-02-01, 51-25-10-02-01, 51-25-15-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801. COMPLIED WITH TC RD 8/4-53-5483. REINSTALLED CROSS BRACE IAW SRM 51-41-05-00-01.