What was found
AFTER REMOVAL OF JUNCTION BOXES AND RACKS TO WORK CORROSION ON THE UPPER FLANGE OF FRAME 32.4, FOUND LOWER FLANGE CORRODED STR 32P-31P. REMOVED CORROSION IAW SRM 51-42-05-02-01, 51-21-00-00-02 AND 53-00-00-02-09. FOUND OUT OF LIMITS IAW SRM 53-20-17-00-01. CONFIRMED CRACK FREE REF NTM 51-00-06-910-801, PT 1. REMOVED LOWER FLANGE IAW RD 8/4-53-5481. CONFIRMED REPAIR AREA CRACK FREE REF NTM 51-00-06-910-801, PT 1. FABRICATED NEW FLANGE AND REPAIR PACKER IAW RD 8/4-53-5481, MATCH DRILLED NEW PART IAW SRM 51-40-07-02-01. CONFIRMED CRACK FREE REF NTM 8.2.1.1, REV 14, ALODINED, PRIMED AND INSTALLED NEW FLANGE AND PACKER IAW RD 8/4-53-5481. RESTORED SURFACE PROTECTION IAW RD 8/4-53-5481. COMPLIED TC RD 8/4-53-5481.