What was found
CORROSION ON INTERNAL ANGLE OF LOWER EMERGENCY DOOR, LOCATED ON BOTTOM CENTER OF DOOR. BLENDED CORROSION IAW SRM 51-21-00-00-02. ALODINED IAW SRM 51-21-1-02-01 MIN THICKNESS NOTED .061" REF NTM 51-00-04-910-801. CONFIRMED CRACK FREE REF NTM 51-00-06-910-801, PT 1. BLENDS WITHIN LIMITS IAW RD 8/4-52-991. APPLIED SURFACE PROTECTION IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. COMPLIED WITH TC RD 8/4-52-991.