What was found
AFT PASSENGER DOOR NR 3 BEAM GOUGED. BLENDED/SMOOTHED DAMAGED AREA AS NEEDED IAW SRM REV 13, 51-14-00-02-04. MIN THICKNESS NOTED .075" REF NTM 51-00-04-910-801, PT 1, REV 9 NOTE: ENDS OF BLEND AREA NOT POSSIBLE WITH WT DUE TO LOCAL GEOMETRY. CONFIRMED CRACK FREE REF NTM 51-00-06-910-801, PT 1, REV 9. RECEIVED ADVANCED EMAIL TO LEAVE BLEND AS IS AND TO RESTORE SURFACE PROTECTION REF JGEA-13-15848395. APPLIED SURFACE PROTECTION IAW SRM 51-21-10-02-01 AND 51-25-10-02-01, REV 13. APPLIED EPC IAW AMM 51-25-01-390-801, REV 42. FOUND BLEND IN LIMITS IAW RD8/4-52-984 ISS 1. COMPLIED WITH TC RD8/4-53-984, WO 120726.