What was found
UPPER EMERGENCY EXIT DOOR FWD AND AFT UPPER MAIN STOPS HAVE WEAR. BLENDED UPPER FWD AND AFT STOPS IAW SRM 51-14-00-02-04, REV 13. CONFIRMED CRACK FREE REF NTM 51-00-06-910-801, PT 1, REV 9. STOPS ARE FOUND TO BE OUT OF LIMITS IAW SRM 52-20-10-02-21, REV 13. ADJUSTMENT OF LOWER STOPS TRANSFERRED FROM NR 80030. WEAR FOUND IN LIMITS IAW RD8/4-52-985 ISS 1. ADJUSTED UPPER EMER EXIT DOOR IAW AMM 52-22-00-820-801, REV 42. OPS CHECKS GOOD, REF TC 522001E201-60399-DMBD, WO 125303 FOR INSTALL OF SURROUNDS AND LINERS. APPLIED SURFACE PROTECTION IAW RD 8/4-52-985, ISSUE 1. COMPLIED WITH TASK CARD RD 8/4-52-985, WO 120726. PERFORMED FUNCTIONAL TEST IAW RD 8/4-52-985 ISS 1 AND AMM 52-22-00-720-801, REV 42, STEP 1-4A(S) AND STEP 5. FUNCTIONAL TEST COMPLETE IAW AMM 52-22-00-720-801, REV 42, PRESSURE LEAK TEST GOOD. RD8/4-52-985 COMPLETE, TC RD8/4-52-985 T PERM REPAIR FOR WEAR ON THE EMER DOOR NR 2 STOP BEAM 85227102 AT THE FWD AND AFT STOP LOCATIONS.