What was found
STRINGER UNDER FLOOR AT APPROX BS 529-547, S26L HAS CORROSION ON AND AROUND RIVETS. REMOVED CORROSION IAW SRM 51-21-00, PROCEDURE 4, ITEM A STEP 2A-2D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER UNDER FLOOR AT APPROX BS 529-547, S26L HAS CORROSION ON AND AROUND RIVETS. REMOVED CORROSION IAW SRM 51-21-00, PROCEDURE 4, ITEM A STEP 2A-2D.