As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME BS 258.5 HAS SURFACE CORROSION ON CLIP BETWEEN STR 29 & 20 LT. REMOVED SURFACE CORROSION ON CLIP BETWEEN STR 29 AND 30 (LH) FS X258.500 BY HAND IAW SRM 51-21-00, PROC 4 ITEM A. ET INSP REF NDTM PT 1 51-00-06, NO DEFECT NOTED. PERFORMED UT INSP IAW NDTM. EVALUATION OF BLENDED AREA PERFORMED, MATERIAL THICKNESS IS .040" NO SIGNIFICANT LOST OF MATERIAL.