What was found
STRINGER AT BS 605-625, S24L HAS CORROSION ON AND AROUND RIVETS. RIVETS REMOVED AT FS 605-625 STR 24L IAW SRM 51-42-05. C/W UT THICK TEST & ET INSPECTION ON REWORKED AREA REF NDTM PT1, 51-00-04 & 51-00-06. MIN THICKNESS =.056". NO DEFECTS NOTED. REMOVED CORROSION REF SRM 51-21-00, PG 2, STEP (A)(1), SURFACE PREPARATION (2) REMOVAL OF LIGHT CORROSION (A)-(D). NOMINAL THICKNESS .050, REF CV STANDARD, CV760, REV-- 12-JAN-00 .056 REMAINING MAT WITHIN LIMITS. INSTALLED RIVET ON STRINGER 24L BETWEEN FS 605-625, REF SRM 51-42-05 & RESTORED FINISH REF SRM 51-25-00.