What was found
STRINGER AT FS 565-585, S29L HAS CORROSION ON AND AROUND RIVETS. REMOVED CORRODED FASTENER (3) FLUSH RIVET ON FS 565-585 ON STL 29L IAW SRM 51-42-05 PROCEDURE 4 ITEM E, STEPS 1-8. INSTALLED NEW FASTENER (3) FLUSH RIVETS AT APPROX FS 565-585 ON STR 29L, IAW SRM 51-42-05 PROCEDURE 4, ITEMS D, STEP 3-8, NO CORROSION FOUND AROUND RIVETS. RESTORED PRIMED AND FINISH TO REWORKED AREA IAW SRM 51-25-10 PROCEDURE 5, ITEM D, STEP 2.